Drying, Paint, Bitumen & Rubber Industries, Medical & Food Industries, Institute, Agriculture requiring Controlled Temp above Ambient
Model | UTS 1.02 A D.Door / Single Door | UTS 1.02 B Double Door | UTS 1.02 C Double Door |
---|---|---|---|
Interior (mm) | 900 x 900 x 900 | 900 x 950 x 1200 | 1200 x 1200 x 1200 |
Heater Wattage “W” | 4 KW | 4.5 KW | 4.5/ 5.0 KW |
Shelves | 2/3 | 3 | 3 |
Temperature Range : | Ambient to 250°C, Controlled from 50°C – 250°C. |
---|---|
Temperature Stability : | +-1°C or 2°C or better In Microprocessor Based PID Temp. Controller model +- 0.5°C |
Housing Material : | CRC / Mild Steel heavy duty having angle Iron Frame at the bottom with castor wheel duly painted / Powder Coated |
Optional : | Double Colour, Door / Top & Panel Grill on request |
Control Panel : | Digital Temp. Controller, Load & Temp. Indicator, Fan Switch, Mains Switch. |
Optional : | Voltmeter / Digital Timer |
Power Consumption : | Single Phase 220/230V, AC +- 10% 50Hz & 3 phase 440V |
Safety Function : | Temp. Overshoot High & Low Alarm with Safety Control |
Duty Cycle : | Continuous |